UST

The apparatus is designed to generate ultrasonic mechanic oscillations with the purpose of therapeutic effect on separate parts of body. 

Аппараты ультразвуковой терапии УЗТ–«Мед ТеКо»

PURPOSE:  the apparatuses are used for treatment of skin diseases, viscera, musculoskeletal and nervous systems. 

FEATURES:

- Availability of control over the contact with the patient’s body,

- Convenient control and monitoring menu with liquid crystal screen,

- Modern microprocessor technology.

 

Used in: physical therapy, stomatology, cosmetology

 

 

Apparatuses are released in three modifications:           

 

UST-1.3.01F – Med TeKo

(two frequencies – 0.88MHz and 2.64 MHz).

________________________

UST-1.01F - Med TeKo

(one frequency – 0.88 MHz).

________________________

UST-3.01F - Med TeKo

 (one frequency – 2.64 MHz).

 

SPECIFICATIONS:

Frequency of ultrasonic vibrations, MHz  2.64 and 0.88

Operation mode:         continuous, pulsed

Nominal duration of modulation pulses:             

- in the pulsed mode, Ms                 2; 4; 10

- in the continuous mode         continuous

Effective intensity of ultrasonic

vibrations, Wt/sm2          0.05; 0.2; 0.4; 0.7; 1

Time values of the timer to set up, min            2; 4; 6; 8; 10; 12

Supply voltage, V                              220

Supply frequency of the apparatus, Hz   50

Power consumption, Wt, no more than   35

Weight, kg, no more than                        3

Size, mm                                     100х260х215

 

FEATURES:

- Availability of control over the contact with the patient’s body,

- Convenient control and monitoring menu with liquid crystal screen,

- Modern microprocessor technology.

 

Used in: physical therapy, stomatology, cosmetology

 

Apparatuses are released in three modifications:           

 

UST-1.3.01F – Med TeKo

(two frequencies – 0.88MHz and 2.64 MHz).

________________________

UST-1.01F - Med TeKo

(one frequency – 0.88 MHz).

________________________

UST-3.01F - Med TeKo

 (one frequency – 2.64 MHz).

 

 

SPECIFICATIONS:

Frequency of ultrasonic vibrations, MHz  2.64 and 0.88

Operation mode:         continuous, pulsed

Nominal duration of modulation pulses:             

- in the pulsed mode, Ms                 2; 4; 10

- in the continuous mode         continuous

Effective intensity of ultrasonic

vibrations, Wt/sm2          0.05; 0.2; 0.4; 0.7; 1

Time values of the timer to set up, min            2; 4; 6; 8; 10; 12

Supply voltage, V                              220

Supply frequency of the apparatus, Hz   50

Power consumption, Wt, no more than   35

Weight, kg, no more than                        3

Size, mm                                     100х260х215